s4bldg:Boiler a owl:Class ;
    rdfs:label "Boiler"@en ;
    dct:isReferencedBy <https://saref.etsi.org/saref4bldg/v1.1.2/>,
        <https://saref.etsi.org/saref4bldg/v2.1.1/> ;
    rdfs:comment "A boiler is a closed, pressure-rated vessel in which water or other fluid is heated using an energy source such as natural gas, heating oil, or electricity. The fluid in the vessel is then circulated out of the boiler for use in various processes or heating applications."@en ;
    rdfs:isDefinedBy <https://saref.etsi.org/saref4bldg/v1.1.2/>,
        <https://saref.etsi.org/saref4bldg/v2.1.1/> ;
    rdfs:seeAlso <https://saref.etsi.org/saref4bldg/v1.1.2/>,
        <https://saref.etsi.org/saref4bldg/v2.1.1/>,
        "https://w3id.org/ifc/IFC4_ADD1#IfcBoiler" ;
    rdfs:subClassOf [ a owl:Restriction ;
            owl:allValuesFrom saref:Measurement ;
            owl:onProperty s4bldg:heatTransferSurfaceArea ],
        [ a owl:Restriction ;
            owl:allValuesFrom saref:Measurement ;
            owl:onProperty s4bldg:nominalEnergyConsumption ],
        [ a owl:Restriction ;
            owl:allValuesFrom saref:Measurement ;
            owl:onProperty s4bldg:nominalPartLoadRatio ],
        [ a owl:Restriction ;
            owl:allValuesFrom saref:Measurement ;
            owl:onProperty s4bldg:outletTemperatureMax ],
        [ a owl:Restriction ;
            owl:allValuesFrom saref:Measurement ;
            owl:onProperty s4bldg:outletTemperatureMin ],
        [ a owl:Restriction ;
            owl:allValuesFrom saref:Measurement ;
            owl:onProperty s4bldg:pressureRating ],
        [ a owl:Restriction ;
            owl:allValuesFrom saref:Measurement ;
            owl:onProperty s4bldg:waterInletTemperatureMax ],
        [ a owl:Restriction ;
            owl:allValuesFrom saref:Measurement ;
            owl:onProperty s4bldg:waterInletTemperatureMin ],
        [ a owl:Restriction ;
            owl:allValuesFrom saref:Measurement ;
            owl:onProperty s4bldg:waterStorageCapacity ],
        [ a owl:Restriction ;
            owl:allValuesFrom xsd:string ;
            owl:onProperty s4bldg:energySource ],
        [ a owl:Restriction ;
            owl:allValuesFrom xsd:boolean ;
            owl:onProperty s4bldg:isWaterStorageHeater ],
        [ a owl:Restriction ;
            owl:allValuesFrom xsd:string ;
            owl:onProperty s4bldg:operatingMode ],
        s4bldg:EnergyConversionDevice ;
    ns1:hiddenLabel "Boiler" ;
    prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcboiler.htm>,
        <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_boilertypecommon.htm> .