Definition in SAREF4BLDG v2.1.1 ontology document
s4bldg:CooledBeam — Cooled beam
- canonical IRI
- https://saref.etsi.org/saref4bldg/v2.1.1/CooledBeam
- label
- Cooled beam
- definition
-
A cooled beam (or chilled beam) is a device typically used to cool air by circulating a fluid such as chilled water through exposed finned tubes above a space. Typically mounted overhead near or within a ceiling, the cooled beam uses convection to cool the space below it by acting as a heat sink for the naturally rising warm air of the space. Once cooled, the air naturally drops back to the floor where the cycle begins again.
Description as a Class
- has super-classes
-
saref:hasProperty value
s4bldg:nominalSupplyWaterTemperatureHeating
saref:hasProperty value s4bldg:nominalWaterFlowCooling
saref:hasProperty value s4bldg:nominalReturnWaterTemperatureCooling
saref:hasProperty value s4bldg:nominalSorroundingTemperatureCooling
saref:hasProperty value s4bldg:coilLength
saref:hasProperty value s4bldg:nominalSupplyWaterTemperatureCooling
saref:hasProperty value s4bldg:nominalReturnWaterTemperatureHeating
saref:hasProperty value s4bldg:nominalCoolingCapacity
saref:hasProperty value s4bldg:waterPressureMin
saref:hasProperty value s4bldg:nominalWaterFlowHeating
saref:hasProperty value s4bldg:nominalHeatingCapacity
saref:hasProperty value s4bldg:coilWidth
saref:hasProperty value s4bldg:waterPressureMax
saref:hasProperty value s4bldg:nominalSorroundingTemperatureHeating
saref:hasProperty value s4bldg:nominalSorroundingHumidityCooling
s4bldg:EnergyConversionDevice
Definition in SAREF4BLDG v1.1.2 ontology document
s4bldg:CooledBeam — Cooled beam
- canonical IRI
- https://saref.etsi.org/saref4bldg/v1.1.2/CooledBeam
- label
- Cooled beam
- definition
-
A cooled beam (or chilled beam) is a device typically used to cool air by circulating a fluid such as chilled water through exposed finned tubes above a space. Typically mounted overhead near or within a ceiling, the cooled beam uses convection to cool the space below it by acting as a heat sink for the naturally rising warm air of the space. Once cooled, the air naturally drops back to the floor where the cycle begins again.
Description as a Class
- has super-classes
-
s4bldg:coilLength only
saref:Measurement
s4bldg:coilWidth only saref:Measurement
s4bldg:nominalCoolingCapacity only saref:Measurement
s4bldg:nominalHeatingCapacity only saref:Measurement
s4bldg:nominalReturnWaterTemperatureCooling only saref:Measurement
s4bldg:nominalReturnWaterTemperatureHeating only saref:Measurement
s4bldg:nominalSorroundingHumidityCooling only saref:Measurement
s4bldg:nominalSorroundingTemperatureCooling only saref:Measurement
s4bldg:nominalSorroundingTemperatureHeating only saref:Measurement
s4bldg:nominalSupplyWaterTemperatureCooling only saref:Measurement
s4bldg:nominalSupplyWaterTemperatureHeating only saref:Measurement
s4bldg:nominalWaterFlowCooling only saref:Measurement
s4bldg:nominalWaterFlowHeating only saref:Measurement
s4bldg:waterPressureMax only saref:Measurement
s4bldg:waterPressureMin only saref:Measurement
s4bldg:finishColor only xsd:string
s4bldg:integratedLightingType only xsd:string
s4bldg:isFreeHanging only xsd:boolean
s4bldg:pipeConnectionEnum only xsd:string
s4bldg:waterFlowControlSystemType only xsd:string
s4bldg:EnergyConversionDevice