Defined in https://saref.etsi.org/saref4bldg/v1.1.2/ as:

FanCycling: Fan is cycled on and off to control duty. TwoSpeedFan: Fan is switched between low and high speed to control duty. VariableSpeedFan: Fan speed is varied to control duty. DampersControl: Dampers modulate the air flow to control duty. BypassValveControl: Bypass valve modulates the water flow to control duty. MultipleSeriesPumps: Turn on/off multiple series pump to control duty. TwoSpeedPump: Switch between high/low pump speed to control duty. VariableSpeedPump: vary pump speed to control duty.

Definition as a Datatype Property

has range
xsd:string

Turtle

@prefix dct: <http://purl.org/dc/terms/> .
@prefix ns1: <http://www.w3.org/2004/02/skos/core#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix s4bldg: <https://saref.etsi.org/saref4bldg/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

s4bldg:CoolingTower rdfs:subClassOf [ a owl:Restriction ;
            owl:allValuesFrom xsd:string ;
            owl:onProperty s4bldg:capacityControl ] .

<https://saref.etsi.org/saref4bldg/v1.1.2/> dct:references s4bldg:capacityControl ;
    dct:subject s4bldg:capacityControl .

<https://saref.etsi.org/saref4bldg/v2.1.1/> dct:references s4bldg:capacityControl ;
    dct:subject s4bldg:capacityControl .

s4bldg:capacityControl a owl:DatatypeProperty ;
    rdfs:label "capacity control"@en ;
    dct:isReferencedBy <https://saref.etsi.org/saref4bldg/v1.1.2/>,
        <https://saref.etsi.org/saref4bldg/v2.1.1/> ;
    rdfs:comment "FanCycling: Fan is cycled on and off to control duty. TwoSpeedFan: Fan is switched between low and high speed to control duty. VariableSpeedFan: Fan speed is varied to control duty. DampersControl: Dampers modulate the air flow to control duty. BypassValveControl: Bypass valve modulates the water flow to control duty. MultipleSeriesPumps: Turn on/off multiple series pump to control duty. TwoSpeedPump: Switch between high/low pump speed to control duty. VariableSpeedPump: vary pump speed to control duty."@en ;
    rdfs:isDefinedBy <https://saref.etsi.org/saref4bldg/v1.1.2/>,
        <https://saref.etsi.org/saref4bldg/v2.1.1/> ;
    rdfs:range xsd:string ;
    rdfs:seeAlso <https://saref.etsi.org/saref4bldg/v1.1.2/>,
        <https://saref.etsi.org/saref4bldg/v2.1.1/> ;
    ns1:hiddenLabel "capacityControl" .