Definition in SAREF4ENER v2.1.1 ontology document
s4ener:Slot — Slot
- canonical IRI
- https://saref.etsi.org/saref4ener/v2.1.1/Slot
- label
- Slot
- definition
- 
      The single steps of a power sequence are represented by slots. A slot is associated with a slot number (while a power sequence is associated with a power sequence identifier). The slot numbers of two power sequences should be considered independent from each other, i.e., slot number 7 of sequence 1 describes a different slot than slot number 7 of sequence 2. Therefore a slot is only uniquely identified in combination with a sequence ID. 
Description as a Class
- has super-classes
- 
        s4ener:hasUsage only 
        s4ener:Usage
 s4ener:belongsTo only s4ener:PowerSequence
 s4ener:slotNumber exactly 1
 s4ener:optionalSlot max 1
 s4ener:slotActivated max 1
 s4ener:hasDefaultDuration max 1
 s4ener:hasDurationUncertainty max 1
 s4ener:hasEarliestStartTime max 1
 s4ener:hasEndTime max 1
 s4ener:hasLatestEndTime max 1
 s4ener:hasMaxDuration max 1
 s4ener:hasMinDuration max 1
 s4ener:hasRemainingPauseTime max 1
 s4ener:hasStartTime max 1
 s4ener:hasUsage min 1 s4ener:Usage
 s4ener:belongsTo exactly 1 s4ener:PowerSequence
- has sub-classes
- s4ener:IncentiveTableSlot
- is in domain of
- s4ener:hasSlotValue
Definition in SAREF4ENER v1.2.1 ontology document
s4ener:Slot — Slot
- canonical IRI
- https://saref.etsi.org/saref4ener/v1.2.1/Slot
- label
- Slot
- definition
- 
      The single steps of a power sequence are represented by slots. A slot is associated with a slot number (while a power sequence is associated with a power sequence identifier). The slot numbers of two power sequences should be considered independent from each other, i.e., slot number 7 of sequence 1 describes a different slot than slot number 7 of sequence 2. Therefore a slot is only uniquely identified in combination with a sequence ID. 
Description as a Class
- has super-classes
- 
        saref:hasTime only 
        saref:Time
 s4ener:hasEnergyValueType only s4ener:Energy
 s4ener:hasPowerValueType only s4ener:Power
 s4ener:belongsTo only s4ener:PowerSequence
 s4ener:slotNumber exactly 1
 saref:hasDescription max 1
 s4ener:optionalSlot max 1
 s4ener:slotActivated max 1
 saref:hasTime max 1 s4ener:DefaultDuration
 saref:hasTime max 1 s4ener:DurationUncertainty
 saref:hasTime max 1 s4ener:EarliestStartTime
 saref:hasTime max 1 s4ener:EndTime
 saref:hasTime max 1 s4ener:LatestEndTime
 saref:hasTime max 1 s4ener:MaxDuration
 saref:hasTime max 1 s4ener:MinDuration
 saref:hasTime max 1 s4ener:RemainingPauseTime
 saref:hasTime max 1 s4ener:StartTime
 s4ener:hasValueType min 1 ( s4ener:Energy or s4ener:Power)
 s4ener:belongsTo exactly 1 s4ener:PowerSequence
- has sub-classes
- s4ener:IncentiveTableSlot
- is in domain of
- s4ener:hasSlotValue
Definition in SAREF4ENER v1.1.2 ontology document
s4ener:Slot — Slot
- canonical IRI
- https://saref.etsi.org/saref4ener/v1.1.2/Slot
- label
- Slot
- definition
- 
      The single steps of a power sequence are represented by slots. A slot is associated with a slot number (while a power sequence is associated with a power sequence identifier). The slot numbers of two power sequences should be considered independent from each other, i.e., slot number 7 of sequence 1 describes a different slot than slot number 7 of sequence 2. Therefore a slot is only uniquely identified in combination with a sequence ID. 
Description as a Class
- has super-classes
- 
        saref:hasTime only 
        saref:Time
 s4ener:hasEnergyValueType only s4ener:Energy
 s4ener:hasPowerValueType only s4ener:Power
 s4ener:belongsTo only s4ener:PowerSequence
 s4ener:slotNumber exactly 1
 saref:hasDescription max 1
 s4ener:optionalSlot max 1
 s4ener:slotActivated max 1
 saref:hasTime max 1 s4ener:DefaultDuration
 saref:hasTime max 1 s4ener:DurationUncertainty
 saref:hasTime max 1 s4ener:EarliestStartTime
 saref:hasTime max 1 s4ener:EndTime
 saref:hasTime max 1 s4ener:LatestEndTime
 saref:hasTime max 1 s4ener:MaxDuration
 saref:hasTime max 1 s4ener:MinDuration
 saref:hasTime max 1 s4ener:RemainingPauseTime
 saref:hasTime max 1 s4ener:StartTime
 s4ener:hasValueType min 1 ( s4ener:Energy or s4ener:Power)
 s4ener:belongsTo exactly 1 s4ener:PowerSequence