Definition of s4ener:nodeRemoteControllable
Defined in https://saref.etsi.org/saref4ener/v1.1.2/ as:
Indicates whether the power profile of a device is configured for remote control (e.g., by an energy management system).This refers to the selection chosen by the user on the remote control feature of the device. If nodeRemoteControllable is equal to FALSE, all the supported power sequences shall set the sequenceRemoteControllable property to FALSE. If nodeRemoteControllable is equal to TRUE, at least one power sequence shall be remotely controllable by setting the sequenceRemoteControllable property to TRUE.
Definition as a Datatype Property
- has range
- xsd:boolean
Turtle
@prefix dct: <http://purl.org/dc/terms/> .
@prefix ns1: <http://www.w3.org/2004/02/skos/core#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix s4ener: <https://saref.etsi.org/saref4ener/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
s4ener:PowerProfile rdfs:subClassOf [ a owl:Restriction ;
owl:cardinality "1"^^xsd:nonNegativeInteger ;
owl:onProperty s4ener:nodeRemoteControllable ] .
<https://saref.etsi.org/saref4ener/v1.1.2/example/heatingsystem#> dct:references s4ener:nodeRemoteControllable .
<https://saref.etsi.org/saref4ener/v1.2.1/example/heatingSystemPowerProfile#> dct:references s4ener:nodeRemoteControllable .
<https://saref.etsi.org/saref4ener/v1.2.1/example/powerProfileExample#> dct:references s4ener:nodeRemoteControllable .
<https://saref.etsi.org/saref4ener/v2.1.1/example/heatingSystemPowerProfile#> dct:references s4ener:nodeRemoteControllable .
<https://saref.etsi.org/saref4ener/v2.1.1/example/powerProfileExample#> dct:references s4ener:nodeRemoteControllable .
<https://saref.etsi.org/saref4ener/v1.1.2/> dct:references s4ener:nodeRemoteControllable ;
dct:subject s4ener:nodeRemoteControllable .
<https://saref.etsi.org/saref4ener/v1.2.1/> dct:references s4ener:nodeRemoteControllable ;
dct:subject s4ener:nodeRemoteControllable .
<https://saref.etsi.org/saref4ener/v2.1.1/> dct:references s4ener:nodeRemoteControllable ;
dct:subject s4ener:nodeRemoteControllable .
s4ener:nodeRemoteControllable a owl:DatatypeProperty ;
rdfs:label "node remote controllable"@en ;
dct:isReferencedBy <https://saref.etsi.org/saref4ener/v1.1.2/>,
<https://saref.etsi.org/saref4ener/v1.1.2/example/heatingsystem#>,
<https://saref.etsi.org/saref4ener/v1.2.1/>,
<https://saref.etsi.org/saref4ener/v1.2.1/example/heatingSystemPowerProfile#>,
<https://saref.etsi.org/saref4ener/v1.2.1/example/powerProfileExample#>,
<https://saref.etsi.org/saref4ener/v2.1.1/>,
<https://saref.etsi.org/saref4ener/v2.1.1/example/heatingSystemPowerProfile#>,
<https://saref.etsi.org/saref4ener/v2.1.1/example/powerProfileExample#> ;
rdfs:comment "Indicates whether the power profile of a device is configured for remote control (e.g., by an energy management system).This refers to the selection chosen by the user on the remote control feature of the device. If nodeRemoteControllable is equal to FALSE, all the supported power sequences shall set the sequenceRemoteControllable property to FALSE. If nodeRemoteControllable is equal to TRUE, at least one power sequence shall be remotely controllable by setting the sequenceRemoteControllable property to TRUE."@en ;
rdfs:isDefinedBy <https://saref.etsi.org/saref4ener/v1.1.2/>,
<https://saref.etsi.org/saref4ener/v1.2.1/>,
<https://saref.etsi.org/saref4ener/v2.1.1/> ;
rdfs:range xsd:boolean ;
rdfs:seeAlso <https://saref.etsi.org/saref4ener/v1.1.2/>,
<https://saref.etsi.org/saref4ener/v1.2.1/>,
<https://saref.etsi.org/saref4ener/v2.1.1/> ;
ns1:hiddenLabel "nodeRemoteControllable" .