Definition of s4bldg:Boiler
Defined in https://saref.etsi.org/saref4bldg/v1.1.2/ as:
A boiler is a closed, pressure-rated vessel in which water or other fluid is heated using an energy source such as natural gas, heating oil, or electricity. The fluid in the vessel is then circulated out of the boiler for use in various processes or heating applications.
Description as a Class
- has super-classes
-
s4bldg:heatTransferSurfaceArea only
saref:Measurement
s4bldg:nominalEnergyConsumption only saref:Measurement
s4bldg:nominalPartLoadRatio only saref:Measurement
s4bldg:outletTemperatureMax only saref:Measurement
s4bldg:outletTemperatureMin only saref:Measurement
s4bldg:pressureRating only saref:Measurement
s4bldg:waterInletTemperatureMax only saref:Measurement
s4bldg:waterInletTemperatureMin only saref:Measurement
s4bldg:waterStorageCapacity only saref:Measurement
s4bldg:energySource only xsd:string
s4bldg:isWaterStorageHeater only xsd:boolean
s4bldg:operatingMode only xsd:string
s4bldg:EnergyConversionDevice
Turtle
@prefix dct: <http://purl.org/dc/terms/> .
@prefix ns1: <http://www.w3.org/2004/02/skos/core#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix prov: <http://www.w3.org/ns/prov#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix s4bldg: <https://saref.etsi.org/saref4bldg/> .
@prefix saref: <https://saref.etsi.org/core/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
<https://saref.etsi.org/saref4bldg/v1.1.2/> dct:references s4bldg:Boiler ;
dct:subject s4bldg:Boiler .
<https://saref.etsi.org/saref4bldg/v2.1.1/> dct:references s4bldg:Boiler ;
dct:subject s4bldg:Boiler .
s4bldg:Boiler a owl:Class ;
rdfs:label "Boiler"@en ;
dct:isReferencedBy <https://saref.etsi.org/saref4bldg/v1.1.2/>,
<https://saref.etsi.org/saref4bldg/v2.1.1/> ;
rdfs:comment "A boiler is a closed, pressure-rated vessel in which water or other fluid is heated using an energy source such as natural gas, heating oil, or electricity. The fluid in the vessel is then circulated out of the boiler for use in various processes or heating applications."@en ;
rdfs:isDefinedBy <https://saref.etsi.org/saref4bldg/v1.1.2/>,
<https://saref.etsi.org/saref4bldg/v2.1.1/> ;
rdfs:seeAlso <https://saref.etsi.org/saref4bldg/v1.1.2/>,
<https://saref.etsi.org/saref4bldg/v2.1.1/>,
"https://w3id.org/ifc/IFC4_ADD1#IfcBoiler" ;
rdfs:subClassOf [ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:heatTransferSurfaceArea ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalEnergyConsumption ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalPartLoadRatio ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:outletTemperatureMax ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:outletTemperatureMin ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:pressureRating ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:waterInletTemperatureMax ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:waterInletTemperatureMin ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:waterStorageCapacity ],
[ a owl:Restriction ;
owl:allValuesFrom xsd:string ;
owl:onProperty s4bldg:energySource ],
[ a owl:Restriction ;
owl:allValuesFrom xsd:boolean ;
owl:onProperty s4bldg:isWaterStorageHeater ],
[ a owl:Restriction ;
owl:allValuesFrom xsd:string ;
owl:onProperty s4bldg:operatingMode ],
s4bldg:EnergyConversionDevice ;
ns1:hiddenLabel "Boiler" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcboiler.htm>,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_boilertypecommon.htm> .