Definition of s4bldg:CooledBeam
Defined in https://saref.etsi.org/saref4bldg/v1.1.2/ as:
A cooled beam (or chilled beam) is a device typically used to cool air by circulating a fluid such as chilled water through exposed finned tubes above a space. Typically mounted overhead near or within a ceiling, the cooled beam uses convection to cool the space below it by acting as a heat sink for the naturally rising warm air of the space. Once cooled, the air naturally drops back to the floor where the cycle begins again.
Description as a Class
- has super-classes
-
s4bldg:coilLength only
saref:Measurement
s4bldg:coilWidth only saref:Measurement
s4bldg:nominalCoolingCapacity only saref:Measurement
s4bldg:nominalHeatingCapacity only saref:Measurement
s4bldg:nominalReturnWaterTemperatureCooling only saref:Measurement
s4bldg:nominalReturnWaterTemperatureHeating only saref:Measurement
s4bldg:nominalSorroundingHumidityCooling only saref:Measurement
s4bldg:nominalSorroundingTemperatureCooling only saref:Measurement
s4bldg:nominalSorroundingTemperatureHeating only saref:Measurement
s4bldg:nominalSupplyWaterTemperatureCooling only saref:Measurement
s4bldg:nominalSupplyWaterTemperatureHeating only saref:Measurement
s4bldg:nominalWaterFlowCooling only saref:Measurement
s4bldg:nominalWaterFlowHeating only saref:Measurement
s4bldg:waterPressureMax only saref:Measurement
s4bldg:waterPressureMin only saref:Measurement
s4bldg:finishColor only xsd:string
s4bldg:integratedLightingType only xsd:string
s4bldg:isFreeHanging only xsd:boolean
s4bldg:pipeConnectionEnum only xsd:string
s4bldg:waterFlowControlSystemType only xsd:string
s4bldg:EnergyConversionDevice
Turtle
@prefix dct: <http://purl.org/dc/terms/> .
@prefix ns1: <http://www.w3.org/2004/02/skos/core#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix prov: <http://www.w3.org/ns/prov#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix s4bldg: <https://saref.etsi.org/saref4bldg/> .
@prefix saref: <https://saref.etsi.org/core/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
<https://saref.etsi.org/saref4bldg/v1.1.2/> dct:references s4bldg:CooledBeam ;
dct:subject s4bldg:CooledBeam .
<https://saref.etsi.org/saref4bldg/v2.1.1/> dct:references s4bldg:CooledBeam ;
dct:subject s4bldg:CooledBeam .
s4bldg:CooledBeam a owl:Class ;
rdfs:label "Cooled beam"@en ;
dct:isReferencedBy <https://saref.etsi.org/saref4bldg/v1.1.2/>,
<https://saref.etsi.org/saref4bldg/v2.1.1/> ;
rdfs:comment "A cooled beam (or chilled beam) is a device typically used to cool air by circulating a fluid such as chilled water through exposed finned tubes above a space. Typically mounted overhead near or within a ceiling, the cooled beam uses convection to cool the space below it by acting as a heat sink for the naturally rising warm air of the space. Once cooled, the air naturally drops back to the floor where the cycle begins again."@en ;
rdfs:isDefinedBy <https://saref.etsi.org/saref4bldg/v1.1.2/>,
<https://saref.etsi.org/saref4bldg/v2.1.1/> ;
rdfs:seeAlso <https://saref.etsi.org/saref4bldg/v1.1.2/>,
<https://saref.etsi.org/saref4bldg/v2.1.1/>,
"https://w3id.org/ifc/IFC4_ADD1#IfcCooledBeam" ;
rdfs:subClassOf [ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:coilLength ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:coilWidth ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalCoolingCapacity ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalHeatingCapacity ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalReturnWaterTemperatureCooling ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalReturnWaterTemperatureHeating ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalSorroundingHumidityCooling ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalSorroundingTemperatureCooling ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalSorroundingTemperatureHeating ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalSupplyWaterTemperatureCooling ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalSupplyWaterTemperatureHeating ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalWaterFlowCooling ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:nominalWaterFlowHeating ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:waterPressureMax ],
[ a owl:Restriction ;
owl:allValuesFrom saref:Measurement ;
owl:onProperty s4bldg:waterPressureMin ],
[ a owl:Restriction ;
owl:allValuesFrom xsd:string ;
owl:onProperty s4bldg:finishColor ],
[ a owl:Restriction ;
owl:allValuesFrom xsd:string ;
owl:onProperty s4bldg:integratedLightingType ],
[ a owl:Restriction ;
owl:allValuesFrom xsd:boolean ;
owl:onProperty s4bldg:isFreeHanging ],
[ a owl:Restriction ;
owl:allValuesFrom xsd:string ;
owl:onProperty s4bldg:pipeConnectionEnum ],
[ a owl:Restriction ;
owl:allValuesFrom xsd:string ;
owl:onProperty s4bldg:waterFlowControlSystemType ],
s4bldg:EnergyConversionDevice ;
ns1:hiddenLabel "CooledBeam" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccooledbeam.htm>,