s4ener:RemainingPauseTime — Remaining pause time

IRI
https://saref.etsi.org/saref4ener/RemainingPauseTime
Is defined by
https://saref.etsi.org/saref4ener/v1.1.2/
https://saref.etsi.org/saref4ener/v1.2.1/
Is referenced by
https://saref.etsi.org/saref4ener/v1.1.2/
https://saref.etsi.org/saref4ener/v1.2.1/
License

Definition in SAREF4ENER v1.2.1 ontology document

s4ener:RemainingPauseTime — Remaining pause time

canonical IRI
https://saref.etsi.org/saref4ener/v1.2.1/RemainingPauseTime
label
Remaining pause time
definition
The duration that the current slot (s4ee:activeSlotNumber) permits being paused. This element SHALL ONLY be present if the power sequence is interruptible. Otherwise, it SHALL be omitted. In case the power sequence is interruptible the following rules apply: If the element is absent this means there is no explicit pause duration restriction for the current slot; a value of 0s denoted the slot does not permit being paused.

Description as a Class

Definition in SAREF4ENER v1.1.2 ontology document

s4ener:RemainingPauseTime — Remaining pause time

canonical IRI
https://saref.etsi.org/saref4ener/v1.1.2/RemainingPauseTime
label
Remaining pause time
definition
The duration that the current slot (s4ee:activeSlotNumber) permits being paused. This element SHALL ONLY be present if the power sequence is interruptible. Otherwise, it SHALL be omitted. In case the power sequence is interruptible the following rules apply: If the element is absent this means there is no explicit pause duration restriction for the current slot; a value of 0s denoted the slot does not permit being paused.

Description as a Class